multilayer pipe technologies , PVC-O extrusion and other solutions that meet diverse customer needs.

What does a Bribox , power converter, do?
400V/50Hz ( Europe ) to world voltages
A Bribox is a 3 phase inverter and does what a VFD, generator and/or power transformer does, but everything combined in 1 device.
In this voltage converter, 400V/50Hz is converted to 200-600V / 50 or 60Hz.
This sounds very nice, are there no limitations? Converting voltage and frequency also shows the limitation, if your mains connection is not big enough to test, a generator is still needed.
BRIBOX |
|||||
---|---|---|---|---|---|
Type |
BB-16 |
BB-32 |
BB-63 |
BB-125 |
|
POWER SUPPLY |
|||||
connection | CEE 16A 5P | CEE 32A 5P | CEE 63A 5P | klem 35mm2 | |
fuse | C 16A | C 32A | C 63A | 125A | |
POWER |
|||||
nominal | 12,5kVA | 25kVA | 50kVA | 100kVA | |
Piek 1 min. | 38kVA - 55A | 64kVA - 95A | 127kVA - 190A | 255kVA - 380A | |
OUTPUTS |
|||||
fuse 190-210V | C 32A | C 63A | C 125A | 250A | |
fuse 220-240V | C 25A | C 50A | C 100A | 200A | |
fuse 380-420V | C 16A | C 32A | C 63A | 125A | |
fuse 420-460V | C 16A | C 32A | C 63A | 125A | |
fuse 460-500V | C 16A | C 25A | C 50A | 100A | |
fuse 550-600V | C 10A | C 25A | C 50A | 100A | |
DIMENSIONS |
|||||
dim. hxbxd (cm) | 88x87x58 | 102x102x111 | 121x102x111 | 167x100x130 | |
weight | 200kg | 425kg | 550kg | 950kg |


What is the difference between testing machine at 50Hz or 60Hz?
Different voltages and especially different frequencies have a big influence on the operation of your machine. If we test a 60Hz motor at 50Hz, this gives the following deviations:
- All engines run 17% slower.
- pumps and blowers give 17% less flow
- Another result is that transport systems run 17% slower!
This effect is further enhanced if we calculate this for pressure and power.
- Pumps, blowers and fans provide 31% less pressure
- Pumps, blowers and fans consume 62% less power, and therefore also emit less heat.
What does the above mean?
for you and the end customer?
We need to test machines at full capacity, then you have the same conditions as the end customer.
- Heat development
- way of falling and/or turning of product
- lag and/or braking time
- water pressure or suction capacity
Of course, no one wants to solve problems at the customer that could have been identified during testing.
A possible extra flight to your customer is also not good for your profit and customer confidence.


What are the benefits of an inverter?
especially compared to a generator
- No odor or noise from the generator in the business premises or office
- No need to run cables from outside to inside, or through aisles
- No need to worry about the generator fuel level
- During the test run, all doors and windows can be closed.
- Do not rent a transformer.
Environmentally friendly, if you use green energy, also test with green energy.
Recent projects

Actemium
Actemium , a VINCI Energies brand focused on industry, plays a pioneering role in the transformation to a 'smart industry '. With a continuous focus on optimising industrial activity, we guide our customers in a smooth transition to the new industrial era.

Stolze
Stolze is the specialist in the field of electrical and water technology, growth lighting, automation and climate technology for horticulture and utilities.